Physical Specifications for Core Components   B


  This appendix describes the following specifications for PortMaster 4 core components:
 

       Interface Specifications

  Table B-1 Interface Specifications

 
  Interface    Specification 
 Ethernet  10BaseT (RJ-45),
10/100BaseT (RJ-45 and MII)
 Asynchronous serial  RJ-45, with data rates up to 115,200bps

 

       Size and Weight Specifications

  Table B-2 Size and Weight Specifications 

 
  Parameter    Metric    U.S. Equivalent 
 Dimensions (HxWxD)  482.6mm wide x 400mm high x 450.9mm deep  19 inches wide x 15.75 inches high x 18 inches deep
 Chassis weight (empty)  26.33 kilograms  58 pounds
 Power supply  2.72 kilograms  6 pounds
 Manager modules and line boards  1.22 to 1.59 kilograms  2.7 to 3.5 pounds

 

       Environmental Specifications

  Table B-3 Environmental Specifications

 
  Parameter    Metric    U.S. Equivalent 
 Operating temperature  5 to 45oC  41 to 113oF
 Storage temperature  -40 to 85oC  -40 to 185oF
 Operating humidity  20 to 80 percent, noncondensing  20 to 80 percent, noncondensing

 
 

       Electrical Specifications

  Table B-4 Electrical Specifications  

 
  Parameter    Specification 
 Input voltage  AC models: Two power units each providing 400W switching with a third providing backup.  DC models: -48VDC.
 Power dissipation  80W per slot.  Total power dissipation for a fully loaded PortMaster 4 is 800W1.
 Power draw  -50VDC fully loaded chassis draws 18 amps.
100VAC fully loaded chassis draws 9 amps.
200VAC fully loaded chassis draws 4.5 amps.
 Memory, manager module  8MB nonvolatile RAM.
16MB dynamic RAM (upgradable to 32MB).
 AC fuses  250V, 2 amps.
 DC fuses  External to the PortMaster 4.
 Cooling, pulling air from front to back  Two 48VDC fans rated at 100CFM at 0 inches of water static pressure.  Two 48VDC fans rated at 50CFM at 0 inches of water static pressure.

  1.  The PortMaster 4 power dissipation exceeds NEBS limits of 27.9W per square foot per foot. Special equipment room cooling might be required.

 