[Top] [Table Of Contents] [Prev] [Next] [Index]
15 out of 16 total pages
 

Provisioning Information   C


  Table C-1 through Table C-5 contain information that you must supply to your telephone service provider when you are ordering ISDN PRI, T1, E1, or T3 service. See Figure 1-1 on page 1-9 for a list of supported ISDN switch types.
  For information on how to configure the PortMaster 4 for ISDN PRI, T1, E1, or T3 service, see the PortMaster 4 Configuration Guide.

  Table C-1 Provisioning Information for ISDN PRI  

 

  Option

  Suggested

  Comments

  One-way or two-way service

  One-way

  One-way service is for inbound calling. Two-way service is for both inbound and outbound calling.

  Alternating circuit-switched voice and data, or circuit-switched data only

  Alternating circuit-switched voice and data

  Alternating circuit-switched voice and data permits ISDN and modem calls. Circuit-switched data permits only ISDN calls.

  Directory numbers

  One, with all channels hunting

  Normally a T1 line has a single telephone number. However, when the line is set up for ISDN B channels, multiple directory numbers are supported.

  Line framing

  Extended super frame (ESF)

  ESF and D4 are supported.

  Line encoding

  Bipolar 8-zero substitution (B8Zs)

  Alternate mark inversion (AMI) or B8ZS are supported.

  Non-facility associated signaling (NFAS)

 

  NFAS is an optional feature.

  Optional Services

  Directory Number Identification Service (DNIS)

  Yes

  One through 10 digits.

  Table C-2 Provisioning Information for Channelized T1 

 

  Option

  Suggested

  Comment

  Two-state dual-tone multifrequency (DTMF)

  Required

 

  Signaling method

  E&M wink

  E&M wink and foreign exchange station (FXS) loop start are supported.

  One-way or two-way service

  One-way

  Two-way service will be supported in a future ComOS release.

  Directory Number Identification Service (DNIS)

  One digit

 

  Table C-3 Provisioning Information for T1 

 

  Option

  Suggested

  Comment

  Line framing

  ESF

  ESF and D4 are supported.

  Line encoding

  B8ZS

  B8ZS and AMI are supported.

  Signalling method

  E&M wink

  E&M wink and foreign exchange station (FXS) loop start are supported.

  Table C-4 Provisioning Information for E1 

 

  Option

  Suggested

  Comment

  Line framing

  CRC4

  CRC4 and FAS are supported.

  Line encoding

  HDB3

  High-density bipolar 3

  Table C-5 Provisioning Information for T3 

 

  Option

  Suggested

  Comment

  Line framing

  M13

 

  Line encoding

  B3ZS

  The T3 Mux board converts bipolar 3-zero substitution (B3ZS) line encoding to nonreturn to zero (NRZ) DS-3 signaling.

 

[Top] [Table Of Contents] [Prev] [Next] [Index]