1. Set the power switch on the IRX to the OFF position.
2. Set the terminal to 9600 baud, 8 data bits, no parity, 1 stop bit, Xon/Xoff software control.
3. Set DIP switch #1 to the UP position.
4. Attach the terminal (or PC) to the console port (S0) using a null modem cable. Refer to Table B-1 in Appendix B for pinouts.
Caution ¯ Before you reapply power, refer to "Safety Recommendations" on page 2-1 and "Power Guidelines" on page 2-4.
5. Set the power switch to the ON position.
6. Observe the boot diagnostics displayed on the console screen. Refer to Figure 4-1 for a sample boot screen in diagnostic mode and Table 4-2 for a description of displayed messages.
Lucent Technologies, Inc. Boot Prom Rev G
Testing System Memory .... 1024K Verifying Load Module Checksum ... Sizing Physical Memory ... 1MB Testing High Memory ... . 1024K |